Skip to content
Draft. This manual is new and still being checked against the software as it is verified. Some pages will change. If something here does not match what you see, the software is right — tell us and we will fix the page.

Boundaries

Setup tree: Boundaries

  • Control: action (ToolButton2)
  • Control: action (ToolButton2)
  • Control: action (ToolButton2)

repeated once for every entry in ThermalState.boundaries

  • Control: choice (ComboRow)
  • Options: Temperature, Flux, Convection, Radiation
  • Control: action (ToolButton2)
  • Control: choice (ComboRow)

Label changes with the case; the source gives these forms: Heat flux, Temperature.

  • Control: value (ValueField)
  • Value modes: none (plain entry)
  • Shown when: !parent.isConvection && !parent.isRadiation

The in-app guidance depends on the case:

  • Positive is heat going into the part.
  • Kelvin. 20 °C is 293.15 K.
  • Control: value (ValueField)
  • Unit: W/m²/K
  • Value modes: none (plain entry)
  • Shown when: parent.isConvection

Still air is about 5, moving air 25, and water in the hundreds.

Label changes with the case; the source gives these forms: Surroundings, Ambient.

  • Control: value (ValueField)
  • Unit: K
  • Value modes: none (plain entry)
  • Shown when: parent.isConvection || parent.isRadiation

Kelvin. 20 °C is 293.15 K.

  • Control: value (ValueField)
  • Value modes: none (plain entry)
  • Shown when: parent.isRadiation

Infrared emissivity, 0 to 1 — not how the surface looks. Polished metal is about 0.05, oxidised steel 0.8, and almost any paint 0.9 whatever its colour.

The application reports no problems against this step.


… marks a value the application computes at run time, so the source carries no fixed text for it.