Skip to content
Draft. This manual is new and still being checked against the software as it is verified. Some pages will change. If something here does not match what you see, the software is right — tell us and we will fix the page.

EM material

Not a setup-tree node. Embedded in the application.

  • Control: action (ToolButton2)
  • Control: value (ValueField)
  • Value modes: none (plain entry)
  • Shown when: !root.conduction

A ratio, not a permittivity in F/m — the solver applies ε₀ = 8.854e-12 itself. Vacuum and air are 1, PTFE 2.1, alumina 9.8, water about 80.

  • Control: value (ValueField)
  • Unit: S/m
  • Value modes: none (plain entry)
  • Shown when: root.conduction

Copper is 5.96e7, aluminium 2.5e7, stainless 1.4e6 — a factor of forty between the first and the last, and it is what decides the heat rather than the voltage.

  • Control: value (ValueField)
  • Value modes: none (plain entry)
  • Shown when: root.magnetic

Not in the material library yet, so typed rather than chosen. Air and non-magnetic metals are 1; mild steel is around 1000 and varies hugely with the field level, so treat a published figure as a starting point rather than a constant.

The application reports no problems against this step.


… marks a value the application computes at run time, so the source carries no fixed text for it.